| MetroLogic 9540 Scanner With Trigger |
| OPERATIONAL |
|
| Light Source |
Visible Laser Diode 650 nm ± 10 nm |
| Laser Power |
0.7 mW (peak ) |
Depth of Scan Field
|
0 mm - 203 mm (0” - 8”) for 0.330 mm (13 mil) bar code
at default setting |
| Width of Scan Field |
64.0 mm (2.5”) @ face; 249 mm (9.8”) @ 203 mm (8.0”)
|
| Scan Speed |
72 ± 2 scan lines per second |
| Scan Pattern |
Single scan line |
| Minimum Bar Width |
0.132 mm (5.2 mi ) |
| InfraRed Activation |
Long Range: 0 mm - 279
mm ± 51 mm (0" - 11" ± 2") Short Range: 0 mm - 102 mm ± 25 mm (0" - 4"
± 1") |
| Decode Capability |
Auto discriminates all standard bar codes; for other symbologies
call Metrologic |
| System Interfaces |
RS232, PC Keyboard Wedge,
Stand-Alone Keyboard, OCIA, IBM 468X/469X, Light Pen Emulation,
USB |
| Print Contrast |
35% minimum reflectance
difference |
| Roll, Pitch, Yaw |
42°, 68°, 52° or 360°, 60°, 60° |
| Beeper Operation |
7 tones or no beep
|
| Number Characters
Read |
Up to 80 data
characters (maximum will vary based on symbology and
density) |
| Indicators (LED) |
Red = Good read / Green = Laser
on, ready to scan / Yellow = CodeGate active (off); auto-trigger mode
(on) |
|
| MECHANICAL |
|
Length Width |
198 mm (7.8")
45 mm (1.8"); at handle / 78 mm
(3.1"); at head |
| Depth |
40 mm (1.6") |
| Weight |
149 g (5.25 oz) |
| Cable |
Standard 2.1 m ( 7' ) straight;
optional 2.7m ( 9' ) coiled; for other cables call Metrologic
|
|
| ELECTRICAL |
|
| Input Voltage |
5 VDC ± 0.25 V |
Power Operating Power
Standby |
825 mW 600 mW |
Current Operating Current
Standby |
165 mA typical @
5VDC 120 mA
typical @ 5VDC |
| DC Transformers |
Class 2; 5.2 VDC @
650mA |
| Laser Class |
CDRH: Class II;
EN60825-1:1994/A11:1996 Class 1 |
| EMC |
FCC Class B |
|
| ENVIRONMENTAL |
|
| Operating Temperature |
0°C to 40°C (32°F to
104°F) |
| Storage Temperature |
-40°C to 60°C (-40°F to
140°F) |
| Humidity |
5% to 95% relative humidity,
non-condensing |
| Light Levels |
Up to 4842 Lux (450
footcandles) |
| Shock |
Designed to withstand 1.5 m
(5') drops |
| Contaminants |
Sealed to resist airborne
particulate contaminants |
| Ventilation |
None required |
|
| |
| MetroLogic 9520 Scanner Without Trigger |
|
Order $225.00 (includes installation instructions and cable for Sharp)
|
| OPERATIONAL |
|
| Light Source |
Visible Laser Diode 650 nm ± 10 nm |
| Laser Power |
0.7 mW (peak ) |
Depth of Scan Field
|
0 mm - 203 mm (0” - 8”) for 0.330 mm (13 mil) bar code
at default setting |
| Width of Scan Field |
64.0 mm (2.5”) @ face; 249 mm (9.8”) @ 203 mm (8.0”)
|
| Scan Speed |
72 ± 2 scan lines per second |
| Scan Pattern |
Single scan line |
| Minimum Bar Width |
0.132 mm (5.2 mi ) |
| InfraRed Activation |
Long Range: 0 mm - 279
mm ± 51 mm (0" - 11" ± 2") Short Range: 0 mm - 102 mm ± 25 mm (0" - 4"
± 1") |
| Decode Capability |
Auto discriminates all standard bar codes; for other symbologies
call Metrologic |
| System Interfaces |
RS232, PC Keyboard Wedge,
Stand-Alone Keyboard, OCIA, IBM 468X/469X, Light Pen Emulation,
USB |
| Print Contrast |
35% minimum reflectance
difference |
| Roll, Pitch, Yaw |
42°, 68°, 52° or 360°, 60°, 60° |
| Beeper Operation |
7 tones or no beep
|
| Number Characters
Read |
Up to 80 data
characters (maximum will vary based on symbology and
density) |
| Indicators (LED) |
Red = Good read / Green = Laser
on, ready to scan / Yellow = CodeGate active (off); auto-trigger mode
(on) |
|
| MECHANICAL |
|
Length Width |
198 mm (7.8")
45 mm (1.8"); at handle / 78 mm
(3.1"); at head |
| Depth |
40 mm (1.6") |
| Weight |
149 g (5.25 oz) |
| Cable |
Standard 2.1 m ( 7' ) straight;
optional 2.7m ( 9' ) coiled; for other cables call Metrologic
|
|
| ELECTRICAL |
|
| Input Voltage |
5 VDC ± 0.25 V |
Power Operating Power
Standby |
825 mW 600 mW |
Current Operating Current
Standby |
165 mA typical @
5VDC 120 mA
typical @ 5VDC |
| DC Transformers |
Class 2; 5.2 VDC @
650mA |
| Laser Class |
CDRH: Class II;
EN60825-1:1994/A11:1996 Class 1 |
| EMC |
FCC Class B |
|
| ENVIRONMENTAL |
|
| Operating Temperature |
0°C to 40°C (32°F to
104°F) |
| Storage Temperature |
-40°C to 60°C (-40°F to
140°F) |
| Humidity |
5% to 95% relative humidity,
non-condensing |
| Light Levels |
Up to 4842 Lux (450
footcandles) |
| Shock |
Designed to withstand 1.5 m
(5') drops |
| Contaminants |
Sealed to resist airborne
particulate contaminants |
| Ventilation |
None required |
| MetroLogic MS7120 Orbit Scanner |
|
Order $399.00 (includes installation instructions and cable for Sharp)
|
| OPERATIONAL |
|
| Light Source |
Visible Laser Diode 650 nm ± 10 nm |
| Minimum Bar Width |
0.13 mm (5.2 mi ) |
Depth of Scan Field
|
0 mm - 216 mm (0” - 8.5”) for 0.330 mm (13 mil) bar code
|
| Width of Scan Field |
60.0 mm (2.4”) @ face; 105 mm (4.1”) @ 216 mm (8.5”)
|
| Scan Speed |
1200 scan lines per second |
| Scan Pattern |
5 fields of 4 parallel lines (omnidirectional) |
| Decode Capability |
Auto discriminates all standard bar codes; for other symbologies
call Metrologic |
| System Interfaces |
RS232, PC Keyboard Wedge,
Stand-Alone Keyboard, OCIA, IBM 46XX, Light Pen Emulation,
Laser Emulation, USB (with an MX009 USB converter cable |
| Print Contrast |
35% minimum reflectance
difference |
| Roll, Pitch, Yaw |
360°, 60°, 60° |
| Beeper Operation |
7 tones or no beep
|
| Number of Characters
Read |
Up to 80 data
characters (maximum will vary based on symbology and
density) |
| Indicators (LED) |
Green = Laser on, ready to scan / Red = Good read, decoding (Indicator colors can be reversed)
(on) |
|
| MECHANICAL |
|
| Height |
150 mm (5.9") |
| Depth |
105 mm (4.1") |
| Weight |
410 grams (14.5 oz) |
| Cable |
Standard 2.1 m ( 7' ) straight;
optional 2.7m ( 9' ) coiled
|
|
| ELECTRICAL |
|
| Input Voltage |
5.2 VDC ± 0.25 V |
Power Operating Power
Standby |
1.0 W typical |
Current Operating Current
Standby |
200 mA typical, 250 mA typical for IBM models
|
| DC Transformers |
Class 2; 5.2 VDC @
650mA |
| Laser Class |
CDRH: Class IIa;
EN60825-1:1994/A11:1996 Class 1 |
| EMC |
FCC, ICES-003 & EN 55022 Class B |
|
| ENVIRONMENTAL |
|
| Operating Temperature |
0°C to 40°C (32°F to
104°F) |
| Storage Temperature |
-40°C to 60°C (-40°F to
140°F) |
| Humidity |
5% to 95% relative humidity,
non-condensing |
| Light Levels |
Up to 4840 Lux (450
footcandles) |
| Shock |
Designed to withstand 1.2 m
(3.9') drops |
| Contaminants |
Sealed to resist airborne
particulate contaminants |
| Ventilation |
None required |
|
| MetroLogic MS3780 Fusion Scanner |
|
Order $399.00 (includes installation instructions and cable for Sharp)
|
| OPERATIONAL |
|
| Light Source |
Visible Laser Diode 650 nm ± 10 nm |
| Minimum Bar Width |
0.127 mm (5.0 mi ) |
Depth of Scan Field
|
25 mm - 279 mm (1” - 11”) for 0.330 mm (13 mil) bar code
|
| Width of Scan Field |
30.0 mm (1.2”) @ face; 25 mm (1.0”) @ 150 mm (5.9”) @ 280 mm (11.0”)
|
| Scan Speed |
1,333 scan lines per second, omnidirectional; 67 scan lines per second, single-line |
| Scan Pattern |
5 fields of 4 parallel lines (omnidirectional);
or button activated single-line |
| Decode Capability |
Auto discriminates all standard bar codes; for other symbologies
call Metrologic |
| System Interfaces |
RS232, PC Keyboard Wedge,
Stand-Alone Keyboard, OCIA, IBM 46XX, USB |
| Print Contrast |
35% minimum reflectance
difference |
| Roll, Pitch, Yaw |
360°, 60°, 60° |
| Beeper Operation |
7 tones or no beep
|
| Number of Characters
Read |
Up to 80 data
characters |
| Indicators (LED) |
Blue = Laser on, ready to scan / White = Good read
(on) |
|
| MECHANICAL |
|
| Length (scanner only) |
189mm(7.44") |
| Width (scanner only) |
65 mm (2.56") |
| Weight (scanner only) |
195 grams (6.9 oz) |
| Cable |
Standard 2.1 m ( 7' ) straight;
optional 2.7m ( 9' ) coiled
|
|
| ELECTRICAL |
|
| Input Voltage |
5 VDC ± 0.25 V |
| Power |
1.375 W typical |
Current Operating Current
Standby |
275 mA typical @ 5 VDC
|
| DC Transformers |
Class 2; 5.2 VDC @
650mA |
| Laser Class |
Class I; IEC60825-1:1993/A1:1997 + A2:2001
Class 1; en60825-1:1994/A11:1996 + A2:2001 |
| EMC |
FCC, ICES-003 & EN 55022 Class A |
|
| ENVIRONMENTAL |
|
| Operating Temperature |
-20°C to 40°C (-4°F to
104°F) |
| Storage Temperature |
-40°C to 60°C (-40°F to
140°F) |
| Humidity |
5% to 95% relative humidity,
non-condensing |
| Light Levels |
Up to 4842 Lux (450
footcandles) |
| Shock |
Designed to withstand 1.5 m
(4.93') drops |
| Contaminants |
Sealed to resist airborne
particulate contaminants |
| Ventilation |
None required |
|
|